181 research outputs found
Two-year visual field outcomes of the treatment for advanced glaucoma study (TAGS)
PURPOSE: to compare visual field (VF) progression between the two arms of the Treatment of Advanced Glaucoma Study (TAGS) DESIGN: post-hoc analysis of VF data from a two-arm multicenter randomized controlled clinical trial METHODS: 453 patients with newly diagnosed advanced open-angle glaucoma in at least one eye from 27 centers in the United Kingdom were randomized to either trabeculectomy (N = 227) or medications in their index eye (N = 226) and followed-up for two years with two 24-2 VF tests at baseline, 4, 12 and 24 months. We analyzed data for participants with a reliable VF (False positive rate < 15%) at baseline and at least two other time-points. MAIN OUTCOME MEASURES: Average difference in rate of progression (RoP) was analyzed using a hierarchical Bayesian model. Time for each eye to progress from baseline beyond specific cut-offs (0.5, 1, 1.5 and 2 dB) was compared using survival analysis. RESULTS: 211 eyes in the trabeculectomy-first arm and 203 eyes in the medications-first arm were analyzed. The average RoPs (Estimate [95% Credible Intervals]) were -0.59 [-0.88, -0.31] dB/year in the medications-first arm and -0.40 [-0.67, -0.13] dB/year in the trabeculectomy-first arm. The difference was not significant (Bayesian p-value = 0.353). More eyes progressed in the medications-first arm: ≥0.5 dB (p = 0.001), ≥1dB (p = 0.014), ≥1.5dB (p = 0.071) and ≥2dB (p = 0.061). CONCLUSIONS: there was no significant difference in the average RoP at two years. Initial trabeculectomy significantly reduced the proportion of progressing eyes
Recommended from our members
Searching for unity: Real-world versus item-based visual search in age-related eye disease
When studying visual search, item-based approaches using synthetic targets and distractors limit the real-world applicability of results. Everyday visual search can be impaired in patients with common eye diseases like glaucoma and age-related macular degeneration. We highlight some results in the literature that suggest assessment of real-word search tasks in these patients could be clinically useful
Recommended from our members
Severity of Visual Field Loss at First Presentation to Glaucoma Clinics in England and Tanzania
Purpose: To compare severity of visual field (VF) loss at first presentation in glaucoma clinics in England and Tanzania.
Methods: Large archives of VF records from automated perimetry were used to retrospectively examine vision loss at first presentation in glaucoma clinics in Tanzania (N = 1,502) and England (N = 9,264). Mean deviation (MD) of the worse eye at the first hospital visit was used as an estimate of detectable VF loss severity.
Results: In Tanzania, 44.7% {CI95%: 42.2, 47.2} of patients presented with severe VF loss (< −20 dB), versus 4.6% {4.1, 5.0} in England. If we consider late presentation to also include cases of advanced loss (-12.01 dB to -20 dB), then the proportion of patients presenting late was 58.1% {55.6, 60.6} and 14.0% {13.3, 14.7}, respectively. The proportion of late presentations was greater in Tanzania at all ages, but the difference was particularly pronounced among working-age adults, with 50.3% {46.9, 53.7} of 18–65-year-olds presenting with advanced or severe VF loss, versus 10.2% {9.3, 11.3} in England. In both countries, men were more likely to present late than women.
Conclusions: Late presentation of glaucoma is a problem in England, and an even greater challenge in Tanzania. Possible solutions are discussed, including increased community eye-care, and a more proactive approach to case finding through the use of disruptive new technologies, such as low-cost, portable diagnostic aids
Recommended from our members
Spatiotemporal summation of perimetric stimuli in healthy observers
Spatial summation of perimetric stimuli has been used to derive conclusions about the spatial extent of retinal-cortical convergence, mostly from the size of the critical area of summation (Ricco's area, RA) and critical number of retinal ganglion cells (RGCs). However, spatial summation is known to change dynamically with stimulus duration. Conversely, temporal summation and critical duration also vary with stimulus size. Such an important and often neglected spatiotemporal interaction has important implications for modeling perimetric sensitivity in healthy observers and for formulating hypotheses for changes measured in disease. In this work, we performed experiments on visually heathy observers confirming the interaction of stimulus size and duration in determining summation responses in photopic conditions. We then propose a simplified computational model that captures these aspects of perimetric sensitivity by modelling the total retinal input, the combined effect of stimulus size, duration, and retinal cones-to-RGC ratio. We additionally show that, in the macula, the enlargement of RA with eccentricity might not correspond to a constant critical number of RGCs, as often reported, but to a constant critical total retinal input. We finally compare our results with previous literature and show possible implications for modeling disease, especially glaucoma
Concomitant Psychiatric and Nonalcohol-Related Substance Use Disorders Among Hospitalized Patients with Alcoholic Liver Disease in the United States
Background
Despite that the epidemiological studies on the comorbidity of alcohol misuse and psychiatric disorders have been studied, less is known about the magnitude of these disorders among patients with alcoholic liver disease (ALD). Our aim was to determine the prevalence of psychiatric and substance use disorders among hospitalized ALD patients in the United States.
Methods
We utilized a single-level clinical classification software to identify patients with ALD and psychiatric/substance use disorders from the 2011 National Inpatient Sample data. The primary outcome was the prevalence of these disorders among hospitalized patients with ALD (n = 74,972) compared to those with chronic liver diseases not caused by alcohol (n = 350,140) and those without underlying liver diseases (n = 1,447,063).
Results
The prevalence of adjustment disorder, anxiety disorder, posttraumatic stress disorder, and depression was significantly higher among hospitalized patients with ALD when compared to those with chronic liver diseases not caused by alcohol (all with p-values <0.05). Younger age, female gender, and White race were the independent predictors of psychiatric/substance use disorders among hospitalized patients with ALD.
Conclusions
Hospitalized patients with ALD have significantly high prevalence of concomitant psychiatric and substance abuse disorders when compared to those with chronic liver diseases not caused by alcohol and those without underlying liver diseases. Screening and appropriate intervention should be implemented as part of routine clinical care for these patients
Testing a phantom eye under various signal-to-noise ratio conditions using eleven different OCT devices
We compared eleven OCT devices in their ability to quantify retinal layer thicknesses under different signal-strength conditions, using a commercially available phantom eye. We analyzed a medium-intensity 50 µm layer in an identical manner for all devices, using the provided log-scale images and a reconstructed linear-scale tissue reflectivity metric. Thickness measurements were highly comparable when the data were analyzed in an identical manner. With optimal signal strength, the thickness of the 50 µm layer was overestimated by a mean of 4.3 µm in the log-scale images and of 2.7 µm in the linear-scale images.</p
Glaucoma Home Monitoring Using a Tablet- Based Visual Field Test (Eyecatcher): An Assessment of Accuracy and Adherence Over 6 Months
PURPOSE: To assess accuracy and adherence of visual field (VF) home monitoring in a pilot sample of patients with glaucoma. DESIGN: Prospective longitudinal feasibility and reliability study. METHODS: Twenty adults (median 71 years) with an established diagnosis of glaucoma were issued a tablet perimeter (Eyecatcher) and were asked to perform 1 VF home assessment per eye, per month, for 6 months (12 tests total). Before and after home monitoring, 2 VF assessments were performed in clinic using standard automated perimetry (4 tests total, per eye). RESULTS: All 20 participants could perform monthly home monitoring, though 1 participant stopped after 4 months (adherence: 98% of tests). There was good concordance between VFs measured at home and in the clinic (r = 0.94, P < .001). In 21 of 236 tests (9%), mean deviation deviated by more than ±3 dB from the median. Many of these anomalous tests could be identified by applying machine learning techniques to recordings from the tablets' front-facing camera (area under the receiver operating characteristic curve = 0.78). Adding home-monitoring data to 2 standard automated perimetry tests made 6 months apart reduced measurement error (between-test measurement variability) in 97% of eyes, with mean absolute error more than halving in 90% of eyes. Median test duration was 4.5 minutes (quartiles: 3.9-5.2 minutes). Substantial variations in ambient illumination had no observable effect on VF measurements (r = 0.07, P = .320). CONCLUSIONS: Home monitoring of VFs is viable for some patients and may provide clinically useful data
The Human Touch:Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments
Purpose: To explore the feasibility of using various easy-to-obtain biomarkers to monitor non-compliance (measurement error) during visual field assessments. Methods: Forty-two healthy adults (42 eyes) and seven glaucoma patients (14 eyes) underwent two same-day visual field assessments. An ordinary webcam was used to compute seven potential biomarkers of task compliance, based primarily on eye gaze, head pose, and facial expression. We quantified the association between each biomarker and measurement error, as defined by (1) test-retest differences in overall test scores (mean sensitivity), and (2) failures to respond to visible stimuli on individual trials (stimuli -3 dB or more brighter than threshold). Results: In healthy eyes, three of the seven biomarkers were significantly associated with overall (test-retest) measurement error (P = 0.003-0.007), and at least two others exhibited possible trends (P = 0.052-0.060). The weighted linear sum of all seven biomarkers was associated with overall measurement error, in both healthy eyes (r = 0.51, P <0.001) and patients (r = 0.65, P <0.001). Five biomarkers were each associated with failures to respond to visible stimuli on individual trials (all P <0.001). Conclusions: Inexpensive, autonomous measures of task compliance are associated with measurement error in visual field assessments, in terms of both the overall reliability of a test and failures to respond on particular trials ("lapses"). This could be helpful for identifying low-quality assessments and for improving assessment techniques (e.g., by discounting suspect responses or by automatically triggering comfort breaks or encouragement). Translational Relevance: This study explores a potential way of improving the reliability of visual field assessments, a crucial but notoriously unreliable clinical measure
Exploring Eye Movements in Patients with Glaucoma When Viewing a Driving Scene
Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT)
Acceptability of a home-based visual field test (Eyecatcher) for glaucoma home monitoring: a qualitative study of patients' views and experiences
Objectives To explore the acceptability of home visual field (VF) testing using Eyecatcher among people with glaucoma participating in a 6-month home monitoring pilot study. Design Qualitative study using face-to-face semistructured interviews. Transcripts were analysed using thematic analysis. Setting Participants were recruited in the UK through an advertisement in the International Glaucoma Association (now Glaucoma UK) newsletter. Participants Twenty adults (10 women; median age: 71 years) with a diagnosis of glaucoma were recruited (including open angle and normal tension glaucoma; mean deviation=2.5 to -29.9 dB). Results All participants could successfully perform VF testing at home. Interview data were coded into four overarching themes regarding experiences of undertaking VF home monitoring and attitudes towards its wider implementation in healthcare: (1) comparisons between Eyecatcher and Humphrey Field Analyser (HFA); (2) capability using Eyecatcher; (3) practicalities for effective wider scale implementation; (4) motivations for home monitoring. Conclusions Participants identified a broad range of benefits to VF home monitoring and discussed areas for service improvement. Eyecatcher was compared positively with conventional VF testing using HFA. Home monitoring may be acceptable to at least a subset of people with glaucoma
- …